Refine your search:     
Report No.
 - 
Search Results: Records 1-2 displayed on this page of 2
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Thermal management of heat resistant FBG sensing for high temperature industrial plants

Nishimura, Akihiko; Takenaka, Yusuke*; Furusawa, Akinori; Torimoto, Kazuhiro; Ueda, Masashi; Fukuda, Naoaki*; Hirao, Kazuyuki*

E-Journal of Advanced Maintenance (Internet), 9(2), p.52 - 59, 2017/08

no abstracts in English

JAEA Reports

Measurement and evaluation of corrosion products deposition distribution in the experimental fast reactor JOYO

Aoyama, Takafumi; *; Sumino, Kozo; Saikawa, Takuya*

PNC TN9410 98-004, 74 Pages, 1997/12

PNC-TN9410-98-004.pdf:2.36MB

The Corrosion Product (CP) is the major radiation source in the primary cooling system of an LNFBR plant. It is important to characterize and predict the CP behavior to reduce the personnel exposure dose due to CP deposition. The CP measurement was carried out in the Experimental Fast Reactor JOYO during the 11th annual inspection period when the accumulated reactor thermal power reached about l43GWd. The CP deposition density was measured using a pure germanium detector. The plastic scintillation fiber (PSF) was applied for the gamma-ray dose rate distri bution measurement and compared with the thermoluminescence dosimeter (TLD). The major results obtained by the CP measurements in JOYO are the follows: (1)The major CP nuclides deposited in the primary cooling system are $$^{54}$$Mn and $$^{60}$$CO. $$^{54}$$Mn is the dominant isotope and it tends to deposit in the cold leg region. On the other hand, $$^{60}$$Co deposits mainly in the hot leg region. The deposition density of $$^{54}$$Mn is about seven times as much as that of $$^{60}$$Co in the cold leg region and twice in the hot leg region. (2)The deposition densities of $$^{54}$$Mn and $$^{60}$$Co, and the gamma-dose rate were decreased from the last data in the previous annual inspection period mainly due to the short operation time and the longer cooling time. (3)The continuous gamma-ray dose rate distribution up to 10m can be measured by using the PSF in a few minutes. The PSF is suitable to measure the gamma-ray dose rate distribution in the maintenance work area where it is narrow and the mixture of gamma-ray sources from primary pipings and components. The data base of detailed gamma-ray dose rate distribution was greatly extended by the PSF.

2 (Records 1-2 displayed on this page)
  • 1